ICES Database
ElectroMagnetic Field Literature
Search Engine
  

EMF Study
(Database last updated on Mar 27, 2024)

ID Number 136
Study Type Human / Provocation
Model 150 MHz (PW 217 Hz) exposure to humans and analysis of EEG
Details

Human subjects (n=17) were exposed to the magnetic field from a 150 MHz signal pulsed at 217 Hz from coils around the neck region. The measured magnetic field strength was ~0.01 µT. Calculated power density in the brain tissue at 6 cm depth was lower than 1 µW/cm2. Exposure was reported to produce changes in EEG recordings (increase in alpha 8-12 Hz activity that continued for several minutes after exposure).

Findings Effects
Status Completed With Publication
Principal Investigator Medical University of Luebech, FRG - klitzing@medinf.mu-luebech.de
Funding Agency Private/Instit.
Country GERMANY
References
  • von Klitzing, I Physica Medica, (1995) :77-80
  • Comments

    It was not clear from the study whether the results were from a single experiment, a single individual, or averaged over multiple experiments and volunteers.